Power-Sonic - PS-4100
| Voltage | 4 Volt |
|---|---|
| Capacity | 10.0 Ah |
| Chemistry | Sealed Lead Acid |
| Rechargeable | Yes |
| Terminal Type | F1 Faston |
| Length | 4.01 |
| Width | 1.97 |
| Height | 3.7 |
| Weight | 2.500000 |
| Warranty | 12 Months |
| Brand | Power-Sonic |
Compatible Devices
Manufacturer
OEM Part Number
Device Type
Product Description
4V 10Ah Battery for Emergency Lighting and Exit Signs
Ensure your facility remains safe and compliant with the Power-Sonic PS-4100, a premium 4V 10Ah sealed lead acid battery designed for critical backup power applications. This versatile battery is the ideal replacement for a wide range of emergency lights, exit signs, fire alarm panels, and security systems. When the power goes out, you can depend on the PS-4100 to keep your life safety systems running.
Featuring Absorbent Glass Mat (AGM) technology, the PS-4100 is a maintenance-free, spill-proof battery that delivers reliable performance and a long service life. Unlike generic, unbranded batteries, the Power-Sonic PS-4100 is a trusted choice for facility managers and electricians who prioritize quality and dependability. It's the perfect solution for ensuring your building meets all fire and safety codes.
Universal Compatibility with Major Brands
This 4V 10Ah battery is a direct replacement for batteries in a wide variety of emergency lighting and fire system equipment. It is compatible with many models from leading manufacturers, including:
- Lithonia Lighting (replaces ELB0410)
- Dual-Lite (replaces 0120770)
- Emergi-Lite (replaces ME-2, M18-018)
- Big Beam Emergency Systems
- Chloride Systems
And many other brands that require a 4V 10Ah sealed lead acid battery.
Frequently Asked Questions (FAQ)
Q: How do I know if I need a 4V battery?
A: The best way is to check the label on your existing battery. Most emergency light and exit sign batteries will have their voltage (4V, 6V, or 12V) printed directly on the case. If you are unsure, consult your equipment's service manual or contact us for assistance.
Q: Is this battery compatible with my specific emergency light model?
A: The PS-4100 is a universal replacement for any equipment that requires a 4V 10Ah sealed lead acid battery with F1 terminals. It is a common replacement for models from Lithonia, Dual-Lite, and Emergi-Lite. Please check your existing battery's dimensions and specifications to ensure a proper fit.
Q: What is the difference between this Power-Sonic battery and a cheaper generic brand?
A: Power-Sonic is a globally recognized brand known for its stringent quality control and reliable performance. While generic batteries may be cheaper, they often have a shorter service life and may not perform as expected in a critical power outage. The PS-4100 is UL and VdS certified, ensuring it meets high safety and reliability standards.
Q: How long does this battery last?
A: The expected service life in a standby application like an emergency light is typically 3-5 years. However, lifespan can be affected by ambient temperature and the frequency of discharge cycles. It is recommended to test your emergency lighting systems regularly and replace batteries according to your facility's maintenance schedule.
Q: Is this battery difficult to install?
A: Installation is typically straightforward for anyone with basic technical skills. It involves opening the equipment housing, disconnecting the old battery's terminals, and connecting the new battery. Always ensure the equipment is de-energized before beginning installation.
Installation and Battery Care
Installation Overview
1. Safety First: Disconnect AC power to the emergency light or exit sign before opening the unit.
2. Access the Battery: Open the equipment housing to access the battery compartment.
3. Disconnect Old Battery: Carefully slide the F1 Faston connectors off the old battery terminals. Note the polarity (red for positive, black for negative).
4. Install New Battery: Place the new PS-4100 in the compartment and connect the terminals, ensuring correct polarity.
5. Restore Power: Close the housing and reconnect AC power. The battery will begin to charge.
Battery Care for Optimal Performance
- Initial Charge: Allow the battery to charge for a full 24 hours after installation.
- Regular Testing: Test your emergency lighting system monthly to ensure the battery is holding a charge and functioning correctly.
- Keep it Cool: High ambient temperatures can reduce the service life of sealed lead acid batteries. Install in a location with adequate ventilation where possible.
- Replacement Cycle: For compliance with fire and safety codes, it is recommended to replace emergency lighting batteries every 3-5 years, or as required by local regulations.
Why Buy From RD Batteries?
As specialists in reliable power solutions, we understand the critical importance of quality batteries for life safety systems. We provide facility managers, electricians, and maintenance professionals with dependable products that offer both performance and value.
- Trusted Brands: We stock genuine Power-Sonic batteries, not cheap generic substitutes.
- Expert Support: Our knowledgeable team can help you find the right battery for your specific application.
- Competitive Value: Get the reliability of a top-tier brand at a competitive price.
- Fast Shipping: We know that compliance can't wait. We offer fast shipping to get your systems back up and running quickly.